Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.437
Filtrar
1.
J Exp Biol ; 227(8)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629316

RESUMO

Filter-feeding demosponges are modular organisms that consist of modules each with one water-exit osculum. Once a mature module has been formed, the weight-specific filtration and respiration rates do not change. Sponge modules only grow to a certain size and for a sponge to increase in size, new modules must be formed. However, the growth characteristics of a small single-osculum module sponge are fundamentally different from those of multi-modular sponges, and a theoretically derived volume-specific filtration rate scales as F/V=V-1/3, indicating a decrease with increasing total module volume (V, cm3). Here, we studied filtration rate (F, l h-1), respiration rate (R, ml O2 h-1), volume-specific (F/V) and weight-specific (F/W) filtration rates, and the ratios F/R and F/W along with growth rates of small single-osculum demosponge Halichondria panicea explants of various sizes exposed to various concentrations of algal cells. The following relationships were found: F/V=7.08V-0.24, F=a1W1.05, and R=a2W0.68 where W is the dry weight (mg). The F/R and F/W ratios were constant and essentially independent of W, and other data indicate exponential growth. It is concluded that the experimental data support the theoretical F/V∝V-1/3.


Assuntos
Poríferos , Água , Animais , Respiração , Filtração , Taxa Respiratória
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 167-172, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605616

RESUMO

A pulse and respiration synchronous detection system is designed to explore the changes of physiological signals in different situations. The system obtains the corresponding signal through STM32 control pulse and respiratory acquisition circuit, calculates and displays real-time parameters such as heart rate and respiratory rate, and transmits the data to the upper computer for storage in the database. The experimental test results show that the system can monitor pulse and respiratory waveform in different situations, and the waveform is in good condition. Compared with medical pulse oximeter, the error of measured heart rate and blood oxygen concentration is less than 3%, and the error of respiratory rate is less than 5% compared with the actual value, which verifies the accuracy of system signal acquisition. The system is small in size, low in cost, and comfortable to wear, and can be applied in experimental research related to pulse and respiratory signals.


Assuntos
Oximetria , Processamento de Sinais Assistido por Computador , Frequência Cardíaca/fisiologia , Taxa Respiratória , Gasometria
3.
Sensors (Basel) ; 24(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610281

RESUMO

In this study, we propose a low-cost piezoelectric flexible pressure sensor fabricated on Kapton® (Kapton™ Dupont) substrate by using aluminum nitride (AlN) thin film, designed for the monitoring of the respiration rate for a fast detection of respiratory anomalies. The device was characterized in the range of 15-30 breaths per minute (bpm), to simulate moderate difficult breathing, borderline normal breathing, and normal spontaneous breathing. These three breathing typologies were artificially reproduced by setting the expiratory to inspiratory ratios (E:I) at 1:1, 2:1, 3:1. The prototype was able to accurately recognize the breath states with a low response time (~35 ms), excellent linearity (R2 = 0.997) and low hysteresis. The piezoelectric device was also characterized by placing it in an activated carbon filter mask to evaluate the pressure generated by exhaled air through breathing acts. The results indicate suitability also for the monitoring of very weak breath, exhibiting good linearity, accuracy, and reproducibility, in very low breath pressures, ranging from 0.09 to 0.16 kPa. These preliminary results are very promising for the future development of smart wearable devices able to monitor different patients breathing patterns, also related to breathing diseases, providing a suitable real-time diagnosis in a non-invasive and fast way.


Assuntos
Respiração , Taxa Respiratória , Humanos , Reprodutibilidade dos Testes , Compostos de Alumínio
4.
Sensors (Basel) ; 24(7)2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38610446

RESUMO

Respiratory problems are common amongst older people. The rapid increase in the ageing population has led to a need for developing technologies that can monitor such conditions unobtrusively. This paper presents a novel study that investigates Wi-Fi and ultra-wideband (UWB) antenna sensors to simultaneously monitor two different breathing parameters: respiratory rate, and exhaled breath. Experiments were carried out with two subjects undergoing three breathing cases in breaths per minute (BPM): (1) slow breathing (12 BPM), (2) moderate breathing (20 BPM), and (3) fast breathing (28 BPM). Respiratory rates were captured by Wi-Fi sensors, and the data were processed to extract the respiration rates and compared with a metronome that controlled the subjects' breathing. On the other hand, exhaled breath data were captured by a UWB antenna using a vector network analyser (VNA). Corresponding reflection coefficient data (S11) were obtained from the subjects at the time of exhalation and compared with S11 in free space. The exhaled breath data from the UWB antenna were compared with relative humidity, which was measured with a digital psychrometer during the breathing exercises to determine whether a correlation existed between the exhaled breath's water vapour content and recorded S11 data. Finally, captured respiratory rate and exhaled breath data from the antenna sensors were compared to determine whether a correlation existed between the two parameters. The results showed that the antenna sensors were capable of capturing both parameters simultaneously. However, it was found that the two parameters were uncorrelated and independent of one another.


Assuntos
Líquidos Corporais , Respiração , Humanos , Idoso , Expiração , Taxa Respiratória , Envelhecimento
5.
Comput Biol Med ; 173: 108335, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38564855

RESUMO

In recent decade, wearable digital devices have shown potentials for the discovery of novel biomarkers of humans' physiology and behavior. Heart rate (HR) and respiration rate (RR) are most crucial bio-signals in humans' digital phenotyping research. HR is a continuous and non-invasive proxy to autonomic nervous system and ample evidence pinpoints the critical role of respiratory modulation of cardiac function. In the present study, we recorded longitudinal (7 days, 4.63 ± 1.52) HR and RR of 89 freely behaving human subjects (Female: 39, age 57.28 ± 5.67, Male: 50, age 58.48 ± 6.32) and analyzed their dynamics using linear models and information theoretic measures. While HR's linear and nonlinear characteristics were expressed within the plane of the HR-RR directed flow of information (HR→RR - RR→HR), their dynamics were determined by its RR→HR axis. More importantly, RR→HR quantified the effect of alcohol consumption on individuals' cardiorespiratory function independent of their consumed amount of alcohol, thereby signifying the presence of this habit in their daily life activities. The present findings provided evidence for the critical role of the respiratory modulation of HR, which was previously only studied in non-human animals. These results can contribute to humans' phenotyping research by presenting RR→HR as a digital diagnosis/prognosis marker of humans' cardiorespiratory pathology.


Assuntos
Sistema Nervoso Autônomo , Taxa Respiratória , Humanos , Masculino , Feminino , Taxa Respiratória/fisiologia , Frequência Cardíaca/fisiologia , Sistema Nervoso Autônomo/fisiologia , Modelos Lineares
6.
Chron Respir Dis ; 21: 14799731241246802, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590151

RESUMO

Measuring respiratory and locomotor muscle blood flow during exercise is pivotal for understanding the factors limiting exercise tolerance in health and disease. Traditional methods to measure muscle blood flow present limitations for exercise testing. This article reviews a method utilising near-infrared spectroscopy (NIRS) in combination with the light-absorbing tracer indocyanine green dye (ICG) to simultaneously assess respiratory and locomotor muscle blood flow during exercise in health and disease. NIRS provides high spatiotemporal resolution and can detect chromophore concentrations. Intravenously administered ICG binds to albumin and undergoes rapid metabolism, making it suitable for repeated measurements. NIRS-ICG allows calculation of local muscle blood flow based on the rate of ICG accumulation in the muscle over time. Studies presented in this review provide evidence of the technical and clinical validity of the NIRS-ICG method in quantifying respiratory and locomotor muscle blood flow. Over the past decade, use of this method during exercise has provided insights into respiratory and locomotor muscle blood flow competition theory and the effect of ergogenic aids and pharmacological agents on local muscle blood flow distribution in COPD. Originally, arterial blood sampling was required via a photodensitometer, though the method has subsequently been adapted to provide a local muscle blood flow index using venous cannulation. In summary, the significance of the NIRS-ICG method is that it provides a minimally invasive tool to simultaneously assess respiratory and locomotor muscle blood flow at rest and during exercise in health and disease to better appreciate the impact of ergogenic aids or pharmacological treatments.


Assuntos
Verde de Indocianina , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Verde de Indocianina/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Músculo Esquelético , Taxa Respiratória , Fluxo Sanguíneo Regional/fisiologia
7.
Int J Mol Sci ; 25(7)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38612431

RESUMO

Idiopathic Interstitial Pneumonias (IIPs) are a heterogeneous group of the broader category of Interstitial Lung Diseases (ILDs), pathologically characterized by the distortion of lung parenchyma by interstitial inflammation and/or fibrosis. The American Thoracic Society (ATS)/European Respiratory Society (ERS) international multidisciplinary consensus classification of the IIPs was published in 2002 and then updated in 2013, with the authors emphasizing the need for a multidisciplinary approach to the diagnosis of IIPs. The histological evaluation of IIPs is challenging, and different types of IIPs are classically associated with specific histopathological patterns. However, morphological overlaps can be observed, and the same histopathological features can be seen in totally different clinical settings. Therefore, the pathologist's aim is to recognize the pathologic-morphologic pattern of disease in this clinical setting, and only after multi-disciplinary evaluation, if there is concordance between clinical and radiological findings, a definitive diagnosis of specific IIP can be established, allowing the optimal clinical-therapeutic management of the patient.


Assuntos
Pneumonias Intersticiais Idiopáticas , Patologistas , Humanos , Consenso , Estudos Interdisciplinares , Taxa Respiratória , Pneumonias Intersticiais Idiopáticas/diagnóstico
8.
PLoS One ; 19(4): e0302024, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603660

RESUMO

Cardiovascular diseases remain the leading global cause of mortality. Age is an important covariate whose effect is most easily investigated in a healthy cohort to properly distinguish the former from disease-related changes. Traditionally, most of such insights have been drawn from the analysis of electrocardiogram (ECG) feature changes in individuals as they age. However, these features, while informative, may potentially obscure underlying data relationships. In this paper we present the following contributions: (1) We employ a deep-learning model and a tree-based model to analyze ECG data from a robust dataset of healthy individuals across varying ages in both raw signals and ECG feature format. (2) We use explainable AI methods to identify the most discriminative ECG features across age groups.(3) Our analysis with tree-based classifiers reveals age-related declines in inferred breathing rates and identifies notably high SDANN values as indicative of elderly individuals, distinguishing them from younger adults. (4) Furthermore, the deep-learning model underscores the pivotal role of the P-wave in age predictions across all age groups, suggesting potential changes in the distribution of different P-wave types with age. These findings shed new light on age-related ECG changes, offering insights that transcend traditional feature-based approaches.


Assuntos
Doenças Cardiovasculares , Envelhecimento Saudável , Adulto , Idoso , Humanos , Eletrocardiografia , Nível de Saúde , Taxa Respiratória
9.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544279

RESUMO

Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for fR monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 Ω⋅%-1 and 9.1 Ω⋅%-1 for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.


Assuntos
Corrida , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica , Taxa Respiratória , Têxteis
10.
Biosensors (Basel) ; 14(3)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38534225

RESUMO

Wheezing is a critical indicator of various respiratory conditions, including asthma and chronic obstructive pulmonary disease (COPD). Current diagnosis relies on subjective lung auscultation by physicians. Enabling this capability via a low-profile, objective wearable device for remote patient monitoring (RPM) could offer pre-emptive, accurate respiratory data to patients. With this goal as our aim, we used a low-profile accelerometer-based wearable system that utilizes deep learning to objectively detect wheezing along with respiration rate using a single sensor. The miniature patch consists of a sensitive wideband MEMS accelerometer and low-noise CMOS interface electronics on a small board, which was then placed on nine conventional lung auscultation sites on the patient's chest walls to capture the pulmonary-induced vibrations (PIVs). A deep learning model was developed and compared with a deterministic time-frequency method to objectively detect wheezing in the PIV signals using data captured from 52 diverse patients with respiratory diseases. The wearable accelerometer patch, paired with the deep learning model, demonstrated high fidelity in capturing and detecting respiratory wheezes and patterns across diverse and pertinent settings. It achieved accuracy, sensitivity, and specificity of 95%, 96%, and 93%, respectively, with an AUC of 0.99 on the test set-outperforming the deterministic time-frequency approach. Furthermore, the accelerometer patch outperforms the digital stethoscopes in sound analysis while offering immunity to ambient sounds, which not only enhances data quality and performance for computational wheeze detection by a significant margin but also provides a robust sensor solution that can quantify respiration patterns simultaneously.


Assuntos
Aprendizado Profundo , Dispositivos Eletrônicos Vestíveis , Humanos , Taxa Respiratória , Sons Respiratórios/diagnóstico , Acelerometria
11.
Sensors (Basel) ; 24(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38474953

RESUMO

The Bio-Radar is herein presented as a non-contact radar system able to capture vital signs remotely without requiring any physical contact with the subject. In this work, the ability to use the proposed system for emotion recognition is verified by comparing its performance on identifying fear, happiness and a neutral condition, with certified measuring equipment. For this purpose, machine learning algorithms were applied to the respiratory and cardiac signals captured simultaneously by the radar and the referenced contact-based system. Following a multiclass identification strategy, one could conclude that both systems present a comparable performance, where the radar might even outperform under specific conditions. Emotion recognition is possible using a radar system, with an accuracy equal to 99.7% and an F1-score of 99.9%. Thus, we demonstrated that it is perfectly possible to use the Bio-Radar system for this purpose, which is able to be operated remotely, avoiding the subject awareness of being monitored and thus providing more authentic reactions.


Assuntos
Radar , Sinais Vitais , Taxa Respiratória , Algoritmos , Emoções , Processamento de Sinais Assistido por Computador
12.
Sensors (Basel) ; 24(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38475194

RESUMO

This article presents an in-depth investigation of wearable microwave antenna sensors (MASs) used for vital sign detection (VSD) and lung water level (LWL) monitoring. The study looked at two different types of MASs, narrowband (NB) and ultra-wideband (UWB), to decide which one was better. Unlike recent wearable respiratory sensors, these antennas are simple in design, low-profile, and affordable. The narrowband sensor employs an offset-feed microstrip transmission line, which has a bandwidth of 240 MHz at -10 dB reflection coefficient for the textile substrate. The UWB microwave sensor uses a CPW-fed line to excite an unbalanced U-shaped radiator, offering an extended simulated operating bandwidth from 1.5 to 10 GHz with impedance matching ≤-10 dB. Both types of microwave sensors are designed on a flexible RO 3003 substrate and textile conductive fabric attached to a cotton substrate. The specific absorption rate (SAR) of the sensors is measured at different resonant frequencies on 1 g and 10 g of tissue, according to the IEEE C95.3 standard, and both sensors meet the standard limit of 1.6 W/kg and 2 W/kg, respectively. A simple peak-detection algorithm is used to demonstrate high accuracy in the detection of respiration, heartbeat, and lung water content. Based on the experimental results on a child and an adult volunteer, it can be concluded that UWB MASs offer superior performance when compared to NB sensors.


Assuntos
Micro-Ondas , Respiração , Humanos , Adulto , Criança , Frequência Cardíaca , Taxa Respiratória , Pulmão
13.
BMJ Open ; 14(3): e082770, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38479743

RESUMO

OBJECTIVES: This study aimed to evaluate the effectiveness of the Trauma Rating Index in Age, Glasgow Coma Scale, Respiratory rate and Systolic blood pressure score (TRIAGES) in predicting 24-hour in-hospital mortality among patients aged 65 years and older with isolated traumatic brain injury (TBI). DESIGN: A retrospective, single-centre cohort study. SETTING: This study was conducted at a government-run tertiary comprehensive hospital. PARTICIPANTS: This study included 982 patients aged 65 years or older with isolated TBI, who were admitted to the emergency department between 1 January 2020 and 31 December 2021. INTERVENTIONS: None. PRIMARY OUTCOME: 24-hour in-hospital mortality was the primary outcome. RESULTS: Among the 982 patients, 8.75% died within 24 hours of admission. The non-survivors typically had higher TRIAGES and lower GCS scores. Logistic regression showed significant associations of both TRIAGES and GCS with mortality; the adjusted ORs were 1.98 (95% CI 1.74 to 2.25) for TRIAGES and 0.72 (95% CI 0.68 to 0.77) for GCS. Receiver operating characteristic (ROC) analysis indicated an area under the ROC curve of 0.86 for GCS and 0.88 for TRIAGES, with a significant difference (p=0.012). However, precision-recall curve (PRC) analysis revealed an area under the PRC of 0.38 for GCS and 0.47 for TRIAGES, without a significant difference (p=0.107). CONCLUSIONS: The TRIAGES system is a promising tool for predicting 24-hour in-hospital mortality in older patients with TBI, demonstrating comparable or slightly superior efficacy to the GCS. Further multicentre studies are recommended for validation.


Assuntos
Lesões Encefálicas Traumáticas , Triagem , Humanos , Idoso , Escala de Coma de Glasgow , Estudos Retrospectivos , Estudos de Coortes , Pressão Sanguínea/fisiologia , Taxa Respiratória , Lesões Encefálicas Traumáticas/diagnóstico , Prognóstico
14.
PLoS One ; 19(3): e0299047, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38437201

RESUMO

Small animal studies in biomedical research often require anesthesia to reduce pain or stress experienced by research animals and to minimize motion artifact during imaging or other measurements. Anesthetized animals must be closely monitored for the safety of the animals and to prevent unintended effects of altered physiology on experimental outcomes. Many currently available monitoring devices are expensive, invasive, or interfere with experimental design. Here, we present MousePZT, a low-cost device based on a simple piezoelectric sensor, with a custom circuit and computer software that allows for measurements of both respiratory rate and heart rate in a non-invasive, minimal contact manner. We find the accuracy of the MousePZT device in measuring respiratory and heart rate matches those of commercial systems. Using the widely-used gas isoflurane and injectable ketamine/xylazine combination, we also demonstrate that changes in respiratory rate are more easily detected and can precede changes in heart rate associated with variations in anesthetic depth. Additional circuitry on the device outputs a respiration-locked trigger signal for respiratory-gating of imaging or other data acquisition and has high sensitivity and specificity for detecting respiratory cycles. We provide detailed instruction documents and all necessary microcontroller and computer software, enabling straightforward construction and utilization of this device.


Assuntos
Anestesia , Anestesiologia , Animais , Camundongos , Dor , Respiração , Taxa Respiratória
15.
Comput Biol Med ; 173: 108343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513388

RESUMO

The analysis of the complex interactions involved in the acute physiological response to apnea-bradycardia events in preterm newborns remains a challenging task. This paper presents a novel integrated model of cardio-respiratory interactions, adapted to preterm newborns. A sensitivity analysis, based Morris' screening method, was applied to study the effects of physiological parameters on heart rate and desaturation, during the simulation of a 15-seconds apnea-bradycardia episode. The most sensitive parameters are associated with fundamental, integrative physiological mechanisms involving: (i) respiratory mechanics (intermediate airways and lung compliance), (ii) fraction of inspired oxygen, (iii) metabolic rates (oxygen consumption rate), (iv) heart rate regulation and (v) chemoreflex (gain). Results highlight the relevant influence of physiological variables, involved in preterm apnea-bradycardia events.


Assuntos
Apneia , Bradicardia , Recém-Nascido , Humanos , Recém-Nascido Prematuro/fisiologia , Respiração , Taxa Respiratória , Oxigênio
16.
Physiol Meas ; 45(3)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38387048

RESUMO

Background and Objective. Sleep-disordered breathing (SDB) poses health risks linked to hypertension, cardiovascular disease, and diabetes. However, the time-consuming and costly standard diagnostic method, polysomnography (PSG), limits its wide adoption and leads to underdiagnosis. To tackle this, cost-effective algorithms using single-lead signals (like respiratory, blood oxygen, and electrocardiogram) have emerged. Despite respiratory signals being preferred for SDB assessment, a lack of comprehensive reviews addressing their algorithmic scope and performance persists. This paper systematically reviews 2012-2022 literature, covering signal sources, processing, feature extraction, classification, and application, aiming to bridge this gap and provide future research references.Methods. This systematic review followed the registered PROSPERO protocol (CRD42022385130), initially screening 342 papers, with 32 studies meeting data extraction criteria.Results. Respiratory signal sources include nasal airflow (NAF), oronasal airflow (OAF), and respiratory movement-related signals such as thoracic respiratory effort (TRE) and abdominal respiratory effort (ARE). Classification techniques include threshold rule-based methods (8), machine learning models (13), and deep learning models (11). The NAF-based algorithm achieved the highest average accuracy at 94.11%, surpassing 78.19% for other signals. Hypopnea detection sensitivity with single-source respiratory signals remained modest, peaking at 73.34%. The TRE and ARE signals proved to be reliable in identifying different types of SDB because distinct respiratory disorders exhibited different patterns of chest and abdominal motion.Conclusions. Multiple detection algorithms have been widely applied for SDB detection, and their accuracy is closely related to factors such as signal source, signal processing, feature selection, and model selection.


Assuntos
Síndromes da Apneia do Sono , Humanos , Síndromes da Apneia do Sono/diagnóstico , Respiração , Taxa Respiratória , Polissonografia/métodos , Algoritmos
17.
Sci Rep ; 14(1): 4050, 2024 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-38374225

RESUMO

Sleep apnea (SA) is associated with risk of cardiovascular disease, cognitive decline, and accidents due to sleepiness, yet the majority (over 80%) of patients remain undiagnosed. Inertial measurement units (IMUs) are built into modern wearable devices and are capable of long-term continuous measurement with low power consumption. We examined if SA can be detected by an IMU embedded in a wristwatch device. In 122 adults who underwent polysomnography (PSG) examinations, triaxial acceleration and triaxial gyro signals from the IMU were recorded during the PSG. Subjects were divided into a training group and a test groups (both n = 61). In the training group, an algorithm was developed to extract signals in the respiratory frequency band (0.13-0.70 Hz) and detect respiratory events as transient (10-90 s) decreases in amplitude. The respiratory event frequency estimated by the algorithm correlated with the apnea-hypopnea index (AHI) of the PSG with r = 0.84 in the test group. With the cutoff values determined in the training group, moderate-to-severe SA (AHI ≥ 15) was identified with 85% accuracy and severe SA (AHI ≥ 30) with 89% accuracy in the test group. SA can be quantitatively detected by the IMU embedded in wristwatch wearable devices in adults with suspected SA.


Assuntos
Síndromes da Apneia do Sono , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Síndromes da Apneia do Sono/diagnóstico , Polissonografia , Algoritmos , Taxa Respiratória
18.
Am J Primatol ; 86(5): e23605, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38342984

RESUMO

Global climate change has transformed predictions of fire seasons in the near future, and record-breaking wildfire events have had catastrophic consequences in recent years. In September 2020, multiple wildfires subjected Oregon to hazardous air quality for several days. In this retrospective cohort study, we aimed to examine prenatal loss, morbidity, and mortality of rhesus (Macaca mulatta) and Japanese macaques (Macaca fuscata) exposed to poor air quality from the nearby wildfires. Detailed medical records from 2014 to 2020 of 580 macaques housed outdoors at a research facility in Beaverton, Oregon were used to evaluate the association between these health outcomes and wildfire smoke exposure. Logistic regression models estimated excess prenatal loss, hospitalization rates, respiratory problems, and mortality during and following the wildfire event, and Kruskal-Wallis statistics were used to determine if infant growth was affected by wildfire smoke exposure. Risk of pregnancy loss (relative risk = 4.1; p < 0.001) and odds of diagnosis with a respiratory problem (odds ratio = 4.47; p = 0.003) were higher in exposed infant macaques compared to nonexposed infants. Infant growth was not affected by poor air quality exposure. Our findings suggest wildfire smoke exposure poses a risk to the health of infants and pregnant individuals and should be monitored more closely in the future.


Assuntos
Fumaça , Incêndios Florestais , Animais , Fumaça/efeitos adversos , Estudos Retrospectivos , Taxa Respiratória , Exposição Ambiental/efeitos adversos , Macaca mulatta , Macaca fuscata
19.
Respir Physiol Neurobiol ; 323: 104229, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38307440

RESUMO

This study investigated the respiratory activity in adult Wistar rats across different behavioral seizure severity induced by pentylenetetrazole (PTZ). Animals underwent surgery for electrodes implantation, allowing simultaneous EEG and diaphragm EMG (DIAEMG) recordings and the respiratory frequency and DIAEMG amplitude were measured. Seizures were acutely induced through PTZ injection and classified based on a pre-established score, with absence-like seizures (spike wave discharge (SWD) events on EEG) representing the lowest score. The respiratory activity was grouped into the different seizure severities. During absence-like and myoclonic jerk seizures, the breathing frequency decreased significantly (∼50% decrease) compared to pre- and post-ictal periods. Pronounced changes occurred with more severe seizures (clonic and tonic) with periods of apnea, especially during tonic seizures. Apnea duration was significantly higher in tonic compared to clonic seizures. Notably, during PTZ-induced tonic seizures the apnea events were marked by tonic DIAEMG contraction (tonic-phase apnea). In the majority of animals (5 out of 7) this was a fatal event in which the seizure-induced respiratory arrest preceded the asystole. In conclusion, we provide an assessment of the respiratory activity in the PTZ-induced acute seizures and showed that breathing dysfunction is more pronounced in seizures with higher severity.


Assuntos
Apneia , Pentilenotetrazol , Ratos , Animais , Pentilenotetrazol/toxicidade , Ratos Wistar , Convulsões/induzido quimicamente , Taxa Respiratória
20.
Thorax ; 79(4): 363-365, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38307845

RESUMO

Remote Vision-Based digital Patient Monitoring (VBPM) of pulse (PR) and respiratory rate (RR) was set up in six single rooms in an acute medical and an orthopaedic ward. We compared 102 PR and 154 RR VBPM measurements (from 27 patients) with paired routine nurse measurements. VBPM measurements of RR were validated by reviewing video footage. Nurse measurements of RR were often 16-18 breaths/minute, and did not match VBPM RR (overestimating at low RR and underestimating at high RR). Nurse measurements of pulse were on average 3.9 beats per minute greater than matched VBPM measurements. VBPM was unobtrusive and well accepted.


Assuntos
Taxa Respiratória , Humanos , Monitorização Fisiológica , Frequência Cardíaca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...